Relief Valve

Print Page

A manual tailstock may be supplied with the rotary table. The tailstock is ground to the same center height as the table (approximately 7.00”). The tailstock has a removable #3 dead center. It also incorporates a      manual quill lock. To lock the quill, rotate the manual quill lock handle clockwise to move the manual quill lock from one side of the tailstock body to the other side. Remove the quill lock handle by rotating it counter-clockwise until the handle is free. Drive out the threaded stud from the tailstock body and move it to the other side of the tailstock body. Replace the quill lock handle. The tailstock should be lubricated with Waylube through the ball oilers, located on the top of the unit. Refer to assembly drawing 3144 for part and      assembly information.